Change country to:

Search results

Triple Crosshead THX 70/150

Nearest Maillefer contacts for USA

KN Manufacturing Solutions LLC

Fiber Optic

5464 Woodrun Ct
GA 30517 Braselton

Tel: +1 770 967 1770

Cell: +1 404 202 9655

Fax: +1 770 967 1770

com;ol.;nms;n/k;ine;iem;i.n;kar

TDC (Technical Development Corporation)

Wire & Cable

11845 Vanstory Drive
NC 28078 Huntersville

Tel: +1-770-337-3347

om;t.c;men;lop;eve;ald;nic;ech;n/t;sto;.ba;irv

Maillefer North America

Pipe & Tube

Phipps Bend Industrial Park<br /> 402 Phipps Bend Road
TN 37873 Surgoinsville

Tel: +1 423 817 2440

Fax: +1 423 212 0131

om;a.c;rus;efe;ill;/ma;jon

Maillefer North America

Wire & Cable

4012 Washington Drive<br /> Upper Chichester
PA 19061 Philadelphia

Tel: +1 972 762 2297

net;er.;lef;ail;a/m;ipa;lat;ri.;lau

Perfect distribution, short residence time

Our Triple Crosshead THX 70/150 ensures high dielectric strength and long life time for HV and EHV cables.

Description

Our Triple Crosshead THX 70/150 is used for three-layer extrusion of MV, HV XLPE and EPR cables. An additional flow distributor for EPR insulation is applied. The dimensioning of the flow channels ensures exact thickness for each layer.

The crosshead is equipped with Bi-Flow distributors. Bi-Flow technology in XLPE extrusion enables more accurate wall thicknesses and improved roundness of the cable. The head can be centred with zero screws prior to extrusion. Each of the three layers can be adjusted independently. The centring screws are equipped with a scale to repeat centring according to earlier production. Centring can also be repeated by locking centring screws with a nut before cleaning the head. The connections between the crosshead and the extruders are fixed when the extruders are movable. This arrangement gives the operator optimum space for crosshead handling. The crosshead design allows quick change of extrusion tools when new cable dimensions are close to the ones in use.

An independently controlled fluid circulation unit is used for the crosshead's temperature control. The heating capacity is at least 18 kW and the cooling capacity 10 kW at 120 °C.

The delivery of the triple crosshead includes a basic triple crosshead for XLPE materials with L-support.

Technical characteristics

Cable diameter 30 - 150 mm
Conductor diameter 15 - 70 mm
Conductor screen thickness 0.5 - 3.0 mm
Insulation thickness 4.0 - 35 mm
Insulation screen thickness 0.4 - 3.0 mm
Weight 750 kg
No. of temperature controlled zones 5
Heating of crosshead body With oil or water

Exact values depend on the assembly.

Options

  • Conductor guiding rollers 
  • Milliken compacting unit
  • Extension for larger conductors
  • Extension for smaller cores

Meet us at wire Southeast ASIA 2017 in Bangkok, Thailand on 19 - 21 September, 2017!

wire South America 2017

Read more

IWCS 2017

Read more

Wire & Cable Arabia 2017

Read more

From our blog Visit blog

Meet Us on Booth 304 at IWCS 2017, Oct 9-10

16.8.2017

R&D Director Dr. Mikko Lahti welcomes you to our booth 304 to discuss high performance and cost effective manufacturing solutions for fiber optic cables. “IWCS is an important venue for the cable and connectivity industry and we are very proud to join the Suppliers’ Exhibition” says Dr.Lahti. Read more

Meet Us on Booth 304 at IWCS 2017, Oct 9-10

Maillefer Combines with Davis-Standard

9.8.2017

Today is definitely an important day for our business. We are pleased to inform you that Maillefer and Davis-Standard have entered into an agreement to combine both our companies. Read more

New High Voltage Catenary Continuous Vulcanizing Line EPL 50/Enter

8.8.2017

A versatile and economical high voltage CCV line for XLPE insulation and crosslinking. Medium voltage cable production is also possible. Read more

New High Voltage Catenary Continuous Vulcanizing Line EPL 50/Enter

Hope to See You in wire South America 2017

2.8.2017

How would you define competitiveness? For us it means increasing the lifetime value of your technology in different production and market circumstances. We do it by empowering people, production and productivity - by equipping you with the right competency. Read more

Hope to See You in wire South America 2017

Growing Undersea Infrastructure Redefines Quality Requirements

26.7.2017

Our factory vulcanized joint know-how provides you with all the needed technology to manufacture factory joints for high voltage subsea XLPE cables. Read more

Growing Undersea Infrastructure Redefines Quality Requirements

Visit us at wire Southeast Asia 2017

19.7.2017

We have the perfect match for each market situation – you can find the winning solution in low-end as well as in high-end categories in almost 20 wire, cable, pipe and tube applications. Our wire & cable production solutions are available for building and automotive wires, dry or jelly filled fiber optic cables, low, medium, high and extra high voltage cables, rubber cables, telecom, LAN, and coaxial cables. Read more

Visit us at wire Southeast Asia 2017

Heavy Wall Without the Heavy Costs

13.7.2017

Are you manufacturing micro-drip laterals? Imagine the costs reductions if you could purchase less costly virgin material or even better, include recycled material. Our extrusion lines offer you such possibilities. Read more

Heavy Wall Without the Heavy Costs

New NCC Module Shortens Degassing Times

6.7.2017

Our Curing Calculation Program NCC is a well-known recipe generator for dry curing CV insulation lines. A new module now includes the function for methane degassing calculation. With it, degassing times can be substantially reduced. Read more

New NCC Module Shortens Degassing Times

Share by email